VIL Power Star-Light 4000watt/48volt
  • VIL Power Star-Light 4000watt/48volt
  • VIL Power Star-Light 4000watt/48volt
  • VIL Power Star-Light 4000watt/48volt
  • VIL Power Star-Light 4000watt/48volt
  • VIL Power Star-Light 4000watt/48volt

VIL Power Star-Light 4000watt/48volt

Features: 35A ~70A automatic 3-stage battery charger; Charge current is Adjustable(25% ,50% ,75%...

Availability:

₦189,800
Quantity:
  • Description
  • Reviews (0)

Features:



  • 35A ~70A automatic 3-stage battery charger;

  • Charge current is Adjustable(25% ,50% ,75%, 100%);

  • Inbuilt pure copper transformer;

  • Low voltage, overload, and high voltage, over temperature protection;

  • Battery/AC priority(option);

  • RS232/Remote switch(option);

  • Generator compatible


Specification



























































































































































































































































































MODEL EP30-1KW EP30-1.5KW EP30-2KW EP30-3KW EP30-4KW EP30-5KW EP30-6KW
Default Battery System Voltage 12V 24V 12V 24V 12V 24V 12V 24V 48V 24V 48V 24V 48V 24V 48V
INVERTER OUTPUT
Rated Power 1000W 1500W 2000W 3000W 4000W 5000W 6000W
Surge Rating (20ms) 3000VA 4500VA 6000VA 9000VA 12000VA 15000VA 18000VA
Capable Of Starting Electric Motor 1HP 2HP 3HP
Waveform Pure sine wave/ same as input (bypass mode)
Nominal Output Voltage RMS 100V/110V/120VAC or 220V/230V/240VAC 220V/230V/240VAC
Output Voltage Regulation +/-10% RMS
Output Frequency 50Hz/60Hz +/-0.3 Hz
Inverter Efficiency(Peak) >88%
Line Mode Efficiency >95%
Power Factor 1.0
Typical Transfer Time 10ms(max)
AC INPUT
Voltage 120VAC/230VAC
Selectable Voltage Range 96~132VAC or 155~280VAC(For Personal Computers) 155~280VAC(For Computers)
Frequency Range 50Hz/60Hz (Auto sensing) 40-80Hz
BATTERY
Minimum Start Voltage 10.0VDC /10.5VDC for12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low Battery Alarm 10.5VDC+/-0.3V for12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low Battery Cutoff 10.0VDC+/-0.3V for12VDC mode (*2 for 24VDC, *4 for 48VDC)
High Voltage Alarm 16.0VDC+/-0.3V for12VDC mode (*2 for 24VDC, *4 for 48VDC)
High Battery Voltage Recover 15.5VDC+/-0.3V for12VDC mode (*2 for 24VDC, *4 for 48VDC)
Idle Consumption-Search Mode <25W when power saver on
CHARGER
Output Voltage Depends on battery type
Charger AC Input Breaker Rating 10A 30A 40A
Overcharge Protection S.D. 15.7VDC for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Maximum Charge Current 35A 20A 45A 25A 65A 35A 75A 45A 30A 65A 35A 70A 40A 75A 50A
BYPASS & PROTECTION
Input Voltage Waveform Sine wave (grid or generator)
Nominal Input Frequency 50Hz or 60Hz
Overload Protection (SMPS Load) Circuit breaker
Output Short Circuit Protection Circuit breaker
Bypass Breaker Rating 10A 30A 40A
Max Bypass Current 10Amp 30Amp 40Amp
MECHANICAL SPECIFICATIONS
Mounting Wall mount
Dimensions (W*H*D) 423*224*180 597*224*181
Net Weight (kg) 15.7 18 16.2 15.5 20.3 19.1 25.3 23.7 24 37.2 34.8 44.15 44 44.15 44
Shipping Dimensions(W*H*D) 570*315*300 755*319*288
Shipping Weight (kg) 18.3 20.6 19 18.1 23.1 21.8 28.1 26.5 26.5 40.8 38.4 48 47.8 48 47.8
OTHER
Operation Temperature Range 0°C to 40°C
Storage Temperature -15°C to 60°C
Audible Noise 60dB MAX
Display LED+LCD
Loading(20GP/40GP/40HQ) 450pcs / 850pcs / 1000pcs 300pcs / 650pcs / 800pcs

Approximate Back-Up Time Table































































Power Rate(w) backup time(H) @1*100Ah backup time(H) @2*100Ah backup time(H) @4*100Ah backup time(H) @4*200Ah backup time(H) @8*200Ah
1000 0.4806 1.602 3.50304 7.6896  
2000 0.2136 0.4806 1.602 3.50304 7.6896
3000 0.1068 0.2848 0.8544 2.136 4.8416
4000   0.2136 0.4806 1.602 3.50304
5000   0.12816 0.34176 1.19616 2.73408
6000   0.1068 0.2848 0.8544 2.136
No reviews yet